Home » Products » Maintenance and cleaning » AusLand > Fully automatic A/C System Maintenance Centre AMC-800 (220V)

  • AusLand - Fully automatic A/C System Maintenance Centre AMC-800 (220V)
 
  • Fully automatic A/C System Maintenance Centre AMC-800 (220V)
 
  • Fully automatic A/C System Maintenance Centre AMC-800 (220V)

Fully automatic A/C System Maintenance Centre AMC-800 (220V)

AMC-800/800A A/C System Maintenance Centre

 

AMC series A/C system maintenance equipment is with the latest design technique which uses the best control principle and the manufacturing process.
AMC-800/AMC-800A A/C System Maintenance Centre is intelligent equipment collecting of the A/C flushing, recovery, recycling, recharging and other functions in one. It’s with the beautiful shape, humanized operation interface, and advanced manufacturing processes to make the A/C maintenance professional and simple.

Item No.:ADMC009-220

Weight:120kg(264.55LB)

Package:68cm*58cm*132cm(Inch:26.77*22.83*51.97)

 Related Download Files:

 

 

 

 .pdf

 .pdf

 .pdf

CE-FC-ROHS
GET GUOTES

GET GUOTES

  X
Submit

1. Features:

 

A、Fully automatic, easy to operate.

B、Internal pipeline of A/C system flushing, effectively cleared the internal greasy and fouling, to restore the A/C system performance.

C、With forward flushing, reverse flushing, and pulse flushing functions, which greatly improve the cleaning effect.

D、Using large-size glass tube with LED backlighting, can effectively observe the entire cleaning process.

E、Vertically installing the HP & LP gauges let the operator be able to observe the pressure parameters timely even in the car.

F、Unique design of the pipeline to achieve the high recycling rate no matter with the gas or the liquid.

G、Easy to operate with the concise operating interface.

H、Designed with large size LCD.

I、Database.

K、With printer.

L、Designed with auxiliary load cell for recharging by the external refrigerant tank. (AMC-800A)

2.Specifications:

 

A、Working conditions: Ambient temperature: 0~50°C Relative humidity: <85%

B、Voltage input: □AC220V±10%~50/60Hz □AC110V±10%~60Hz

C、Compressor:12.12cm3

D、Vacuum pump: 7.2m3/h,10Pa

E、Load cell for tank: ±10g

F、Auxiliary load cell: ±10g (AMC-800A)

G、Load cell for oil bottle: ±5g

H.Tank: 12L

I、Oil bottle: 260ml,double

J、LCD display: 240*128

K、Working pressure: max. 17.5bar

L、HP gauge: -1bar~3.5MPa

M、LP gauge: -1bar~1.5MPa

N、Backlighting:LED

3、Functions:

1) Primary functions

 

A、Automatic flushing

B、Automatic recovering/recycling

C、Automatic/manual used oil drain

D、Automatic vacuum

E、Automatic/manual new oil injection

F、Automatic recharging with load cell

G、Automatic recharging via the secondary recharging tank (800A)

H、Auto mode

I、Database

2) Subsidiary functions

A、Parameter setting

B、Supply refrigerant

C、Electric scale calibration

D、Maintenance procedures (dry-filter exchange, vacuum pump maintenance)

E、Printer checking

F、System inquiry

G、Equipment info

H、Help